KRD12 series shock test system is used to measure and determine the horizontal impact resistance of a product or package, and to evaluate the reliability and structural integrity of the test unit in a horizontal impact environment. The system can perform conventional half-sine wave, post-peak sawtooth wave, or square wave shock test to realize the shock energy that the product is subjected to in the actual environment, thereby improving the product or packaging structure.
l Windows-based stable control system, full-automatic remote-control interface
l Pneumatic cylinder driving with advantages of large driving force, short accelerating stroke, low cost and pollution free.
l Trapezoidal guide posts: large supporting force, good lubricity and full-automatic positioning table.
l Automatic control of shock speed: the shock overload value is achieved by adjusting the air pressure. After the cylinder pressure is set, system will automatically control the shock speed with high accuracy and good repeatability.
l Adopts the high strength and hardness cast aluminum table, which has high first-order resonance frequency, featured with low noise and no clutter
l The most reliable double-brake system: effectively avoids secondary rebound collisions, more securely positioning the table, and more reliably guarantees the safety of the operator.
l Multiple waveforms: can perform conventional half-sine waves, post-peak sawtooth waves, or square waves.
l Integrated control & measurement system: the system comes with a variety of waveform tolerance bands that comply with the MIL-810 standard, automatically generates test reports after the test is completed.
l Bidirectional shock: the system can be designed as a bidirectional shock according to user needs, saving test time more effectively.
l Optional foundation free: air springs and dampers are used to reduce vibration.
Technical Specifications
Model
Parameters
|
KRD12-10
|
KRD12-50
|
KRD12-100
|
KRD12-200
|
KRD12-500
|
KRD12-1000
|
KRD12-2000
|
KRD12-3000
|
Rated Load (kg)
|
10
|
50
|
100
|
200
|
500
|
1000
|
2000
|
3000
|
Table Size (mm)
|
200×200
|
500×500
|
600×600
|
800×800
|
1000×1000
|
1200×1200
|
1500×1500
|
2000×2000
|
Peak Acc. (g)
|
Half-Sine
|
10-5000
|
10~1500
|
10~1000
|
10-800
|
10-600
|
10-500
|
10-200
|
10-150
|
Post-Peak
Sawtooth
|
10~200
|
10~100
|
10~50
|
Trapezoid
|
/
|
15~200
|
15~200
|
15-100
|
15-60
|
15-60
|
15-50
|
30-50
|
Pulse Duration (ms)
|
Half-Sine
|
0.3~40
|
1~60
|
1.5~60
|
2~60
|
2.5~60
|
3~60
|
6~60
|
8~60
|
Post-Peak
Sawtooth
|
3~18
|
6~18
|
Trapezoid
|
/
|
3~18
|
6~18
|
Bump Waveform
(Optional)
|
Half sine Waveform
|
Bump Peak Acceleration
(g)
|
5-150
|
5-100
|
5-80
|
5-60
|
/
|
Bump Pulse Duration (ms)
|
2-30
|
3-30
|
4-30
|
/
|
Bump Rate
(Times/Min)
|
10 ~ 120
|
10-80
|
10-60
|
10-40
|
/
|
Overall Dimension
(mm)
|
2950×1240×1000
|
3300×1150×850
|
3500×1240×1100
|
3740×1440×1050
|
4250×1450
×1100
|
4500×1650×850
|
5500×2000×850
|
6000×2200×850
|
Weight (kg)
|
3700
|
3600
|
4800
|
5856
|
6500
|
7000
|
8000
|
9000
|
Working Environment
|
Temperature range 0~40℃, Humidity ≤ 80% (non-condensing)
|
Power
|
1-phase AC220V±10% 50Hz
|
Air source
|
≤1MPa
|
Installation Condition
|
Special foundation, foundation-free base is optional. The working distance of 800~1000mm shall be reserved around the equipment.
|
Standard
|
MIL-STD-810F IEC68-2-27 MIL-STD-202 MIL-STD-750 MIL-STD-883 UN38.3 IEC62281 IEC62133-2 UL2054 IEEE1625 SAEJ2929 IEC62660-2 ISO12405-3 UL2580
|