KRD12 series shock test system is used to measure and determine the horizontal impact resistance of a product or package, and to evaluate the reliability and structural integrity of the test unit in a horizontal impact environment. The system can perform conventional half-sine wave, post-peak sawtooth wave, or square wave shock test to realize the shock energy that the product is subjected to in the actual environment, thereby improving the product or packaging structure.
l Windows-based stable control system, full-automatic remote-control interface
l Pneumatic cylinder driving with advantages of large driving force, short accelerating stroke, low cost and pollution free.
l Trapezoidal guide posts: large supporting force, good lubricity and full-automatic positioning table.
l Automatic control of shock speed: the shock overload value is achieved by adjusting the air pressure. After the cylinder pressure is set, system will automatically control the shock speed with high accuracy and good repeatability.
l Adopts the high strength and hardness cast aluminum table, which has high first-order resonance frequency, featured with low noise and no clutter
l The most reliable double-brake system: effectively avoids secondary rebound collisions, more securely positioning the table, and more reliably guarantees the safety of the operator.
l Multiple waveforms: can perform conventional half-sine waves, post-peak sawtooth waves, or square waves.
l Integrated control & measurement system: the system comes with a variety of waveform tolerance bands that comply with the MIL-810 standard, automatically generates test reports after the test is completed.
l Bidirectional shock: the system can be designed as a bidirectional shock according to user needs, saving test time more effectively.
l Optional foundation free: air springs and dampers are used to reduce vibration.
Technical Specifications
Model Parameters |
KRD12-10 |
KRD12-50 |
KRD12-100 |
KRD12-200 |
KRD12-500 |
KRD12-1000 |
KRD12-2000 |
KRD12-3000 |
||||
Rated Load (kg) |
10 |
50 |
100 |
200 |
500 |
1000 |
2000 |
3000 |
||||
Table Size (mm) |
200×200 |
500×500 |
600×600 |
800×800 |
1000×1000 |
1200×1200 |
1500×1500 |
2000×2000 |
||||
Peak Acc. (g)
|
Half-Sine |
10-5000 |
10~1500 |
10~1000 |
10-800 |
10-600 |
10-500 |
10-200 |
10-150 |
|||
Post-Peak Sawtooth |
10~200 |
10~100 |
10~50 |
|||||||||
Trapezoid |
/ |
15~200 |
15~200 |
15-100 |
15-60 |
15-60 |
15-50 |
30-50 |
||||
Pulse Duration (ms) |
Half-Sine |
0.3~40 |
1~60 |
1.5~60 |
2~60 |
2.5~60 |
3~60 |
6~60 |
8~60 |
|||
Post-Peak Sawtooth |
3~18 |
6~18 |
||||||||||
Trapezoid |
/ |
3~18 |
6~18 |
|||||||||
Bump Waveform (Optional) |
Half sine Waveform |
|||||||||||
Bump Peak Acceleration (g) |
5-150 |
5-100 |
5-80 |
5-60 |
/ |
|||||||
Bump Pulse Duration (ms) |
2-30 |
3-30 |
4-30 |
/ |
||||||||
Bump Rate (Times/Min) |
10 ~ 120 |
10-80 |
10-60 |
10-40 |
/ |
|||||||
Overall Dimension (mm) |
2950×1240×1000 |
3300×1150×850 |
3500×1240×1100 |
3740×1440×1050 |
4250×1450 ×1100 |
4500×1650×850 |
5500×2000×850 |
6000×2200×850 |
||||
Weight (kg) |
3700 |
3600 |
4800 |
5856 |
6500 |
7000 |
8000 |
9000 |
||||
Working Environment |
Temperature range 0~40℃, Humidity ≤ 80% (non-condensing) |
|||||||||||
Power |
1-phase AC220V±10% 50Hz |
|||||||||||
Air source |
≤1MPa |
|||||||||||
Installation Condition |
Special foundation, foundation-free base is optional. The working distance of 800~1000mm shall be reserved around the equipment. |
|||||||||||
Standard |
MIL-STD-810F IEC68-2-27 MIL-STD-202 MIL-STD-750 MIL-STD-883 UN38.3 IEC62281 IEC62133-2 UL2054 IEEE1625 SAEJ2929 IEC62660-2 ISO12405-3 UL2580 |