KRD11 series pneumatic vertical shock/bump test system is suitable for evaluating the functional reliability and structural integrity of various products under shock or bump environments, thereby improving or optimizing the structural design or layout of the products. The system meets the requirements of both shock and bump test, can perform conventional half-sine wave, post-peak sawtooth wave, square wave and other waveform shock tests.
l Pneumatic drive without hydraulic leak risk and keep the environment clean.
l Maximum shock rate up to 120 times / min.
l It can easily realize large pulse width and small overload test.
l The speed and rate of shock can be easily controlled by adjusting the gas pressure.
l IPS-2000 shock control and measurement system can perform manual shock, continuous shock, single shock, and interval shock.
l Built-in brake mechanism ensures the safety of operation in any situation.
l Optional foundation free: air springs and dampers are used to reduce vibration.
Technical Specifications
Model
Parameters
|
KRD
11-5
|
KRD
11-15
|
KRD
11-25
|
KRD
11-50
|
KRD
11-100
|
KRD
11-200
|
KRD
11-400
|
KRD
11-600
|
KRD
11-800
|
KRD
11-1000
|
KRD
11-2000
|
Rated Load (kg)
|
5
|
15
|
25
|
50
|
100
|
200
|
400
|
600
|
800
|
1000
|
2000
|
Table Size (mm)
|
150×150
|
200×200
|
300×300
|
500×500
|
600×600
|
800×600
|
800×800
|
1000×800
|
1000×1000
|
1200×1200
|
1500×1200
|
Peak Acc. (g)
|
Half-Sine
|
5-2500
|
5-2000
|
5-1500
|
10-750
|
10-600
|
10-450
|
10-400
|
10-300
|
10~300
|
10~250
|
10~150
|
Post-Peak
Sawtooth
|
10-200
|
10-100
|
10-50
|
Trapezoid
|
/
|
15-200
|
15-100
|
15-60
|
15-50
|
Pulse Duration (ms)
|
Half-Sine
|
0.4~40
|
0.5~40
|
0.6~60
|
1.5~60
|
2~60
|
2.5~60
|
3~60
|
3.5~60
|
4~60
|
4.5~60
|
6~60
|
Post-Peak
Sawtooth
|
3~18
|
6~18
|
Trapezoid
|
/
|
3~18
|
6~18
|
Bump Waveform
(Optional)
|
Half-sine Waveform
|
Bump Peak Acceleration
(g)
|
5~150
|
5~120
|
5~100
|
5~80
|
5~60
|
5~40
|
/
|
Bump Pulse Duration (ms)
|
2~30
|
3~30
|
4 ~ 30
|
5 ~ 30
|
/
|
Bump Rate
(Times/Min)
|
10~120
|
10~100
|
10~80
|
10~60
|
10~40
|
10~30
|
/
|
Overall Dimension (mm)
|
1000×1000
×2100
|
1000×1000
×2160
|
1510×1300
×2400
|
1690×1240
×2350
|
1710×1160
×2350
|
1910×1500
×2700
|
1910×1500
×2500
|
1900×1500
×2450
|
2000×1500
×2450
|
1900×1800
×2550
|
2200×1800
×2550
|
Weight (kg)
|
1300
|
2300
|
3000
|
3070
|
3900
|
4500
|
5000
|
5200
|
5600
|
6200
|
7300
|
Working Environment
|
Temperature range 0 ~ 40℃, Humidity≤80% (non-condensing)
|
Power
|
1-phase AC220V±10% 50Hz
|
Air source
|
≤0.8MPa
|
Installation
Condition
|
Foundation-free, the cement floor shall be leveled and the working distance of 800~1000mm shall be reserved around the equipment
|
Standards
|
MIL-STD-810F IEC68-2-27 MIL-STD-202 MIL-STD-750 MIL-STD-883 UN38.3 IEC62281 IEC62133-2 UL2054 IEEE1625 SAEJ2929 IEC62660-2 ISO12405-3 UL2580
|